CVE-2026-98590

Published Oct 18, 2026 Modified Oct 19, 2026

Description

In the Linux kernel, the following vulnerability has been resolved: bpf: Fix bpf_sock context code generation Currently, the ctx access code reads the rx_queue_mapping field with either a 4-byte or 2-byte load. The rest of the bits in the register are marked known zero by the verifier. However, the emitted ctx access code places in the register on certain the special value (-1) using BPF_MOV_IMM64, which gets sign-extended to turn on all the bits in the register. By shifting this value right, the program ends up with a value at runtime above what the verifier assumes is possible. Fix this by ensuring the read value is as wide as the assumed size. Use MOV32 instructions instead of MOV64 instructions to keep the upper bits zero as assumed by the verifier. Also properly report the size of the destination variable (the bpf_sock field, 4 bytes) instead of the source (the socket field, 2 bytes).

Is your site exposed to CVE-2026-98590?

Run a free security scan — no signup, results in seconds.

EPSS — Exploit Prediction

0.0022
Probability of exploitation
0.12%
Percentile rank

EPSS estimates the probability that this vulnerability will be exploited in the wild within the next 30 days. A higher score means more likely to be exploited.

References

Frequently Asked Questions

What is CVE-2026-98590? +
In the Linux kernel, the following vulnerability has been resolved: bpf: Fix bpf_sock context code generation Currently, the ctx access code reads the rx_queue_mapping field with either a 4-byte or 2-byte load. The rest of the bits in the register are marked known zero by the verifier. However, the emitted ctx access code places in the register on certain the special value (-1) using BPF_MOV_IMM64, which gets sign-extended to turn on all the bits in the register. By shifting this value right, the program ends up with a value at runtime above what the verifier assumes is possible. Fix this by ensuring the read value is as wide as the assumed size. Use MOV32 instructions instead of MOV64 instructions to keep the upper bits zero as assumed by the verifier. Also properly report the size of the destination variable (the bpf_sock field, 4 bytes) instead of the source (the socket field, 2 bytes).
How do I check if I'm vulnerable to CVE-2026-98590? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-98590 — free, no signup required.

Patch and protect

Block known exploits with a web application firewall while you patch, keep your own devices clean, or test the fix on a fresh server.

Compare VPS prices →

Affiliate links: we may earn a commission, your price stays the same.