CVE-2026-92395

CRITICAL
Published Sep 16, 2026 Modified Sep 16, 2026 CWE-290 CWE-348 CWE-697

Description

@fastify/proxy-addr is a Fastify plugin that determines a request's client address behind trusted reverse proxies, and it backs Fastify request.ip and request.ips. In versions 3.0.0 through 5.1.0, a trust subnet written in IPv4-mapped IPv6 notation with an IPv4-sized prefix, such as ::ffff:10.0.0.0/8 instead of the correct ::ffff:10.0.0.0/104, is accepted without error but trusts every IPv4 address on the internet rather than the block it names. Because the socket peer then becomes trusted at hop 0, any unauthenticated client can supply an arbitrary X-Forwarded-For header and control the address the application reads, which defeats IP-based access control, rate limiting, geolocation, and audit logging. The plugin inherited this defect from the upstream proxy-addr module (CVE-2026-90711). The issue is fixed in @fastify/proxy-addr 5.1.1, and users should upgrade to 5.1.1 or later. As a workaround, ensure any IPv4-mapped IPv6 trust subnet uses a prefix length of at least 97, or express the range in plain IPv4 notation.

Is your site exposed to CVE-2026-92395?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

9.1
CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Weakness Type (CWE)

CWE-290 CWE-290
CWE-348 CWE-348
CWE-697 CWE-697

References

Frequently Asked Questions

What is CVE-2026-92395? +
@fastify/proxy-addr is a Fastify plugin that determines a request's client address behind trusted reverse proxies, and it backs Fastify request.ip and request.ips. In versions 3.0.0 through 5.1.0, a trust subnet written in IPv4-mapped IPv6 notation with an IPv4-sized prefix, such as ::ffff:10.0.0.0/8 instead of the correct ::ffff:10.0.0.0/104, is accepted without error but trusts every IPv4 address on the internet rather than the block it names. Because the socket peer then becomes trusted at hop 0, any unauthenticated client can supply an arbitrary X-Forwarded-For header and control the address the application reads, which defeats IP-based access control, rate limiting, geolocation, and audit logging. The plugin inherited this defect from the upstream proxy-addr module (CVE-2026-90711). The issue is fixed in @fastify/proxy-addr 5.1.1, and users should upgrade to 5.1.1 or later. As a workaround, ensure any IPv4-mapped IPv6 trust subnet uses a prefix length of at least 97, or express the range in plain IPv4 notation. It has a CVSS v3.1 base score of 9.1 (CRITICAL).
How severe is CVE-2026-92395? +
CVE-2026-92395 has a CVSS v3.1 score of 9.1 out of 10, rated CRITICAL. This is a critical vulnerability that should be patched immediately.
How do I check if I'm vulnerable to CVE-2026-92395? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-92395 — free, no signup required.