CVE-2026-10674

MEDIUM
Published Jul 21, 2026 CWE-617

Description

The NXP LPUART serial driver (drivers/serial/uart_mcux_lpuart.c), when CONFIG_UART_USE_RUNTIME_CONFIGURE is enabled, called LPUART_Deinit() at the start of mcux_lpuart_configure(), which disables the LPUART peripheral clocks. The requested configuration is validated only afterwards (in mcux_lpuart_configure_basic), and unsupported parity/data-bit/stop-bit/flow-control values return -ENOTSUP before the clock is re-enabled. As a result, a uart_configure() request with an unsupported configuration left the LPUART in a clock-disabled state; any subsequent access to LPUART registers (poll_out/poll_in, interrupt handling, or a later reconfigure) faults on the gated peripheral and escalates to a hard fault, crashing the system. uart_configure() is a Zephyr syscall whose verifier (z_vrfy_uart_configure) only checks that cfg is readable user memory and forwards the caller-supplied configuration unchanged, so an unprivileged userspace thread with access to an LPUART device can deterministically trigger the fault, a persistent system-wide denial of service. Introduced in v2.5.0 and present in all subsequent releases until this fix, which removes the LPUART_Deinit() call and instead only disables the transmitter/receiver, leaving the clock running.

Is your site exposed to CVE-2026-10674?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Weakness Type (CWE)

CWE-617 CWE-617

References

Frequently Asked Questions

What is CVE-2026-10674? +
The NXP LPUART serial driver (drivers/serial/uart_mcux_lpuart.c), when CONFIG_UART_USE_RUNTIME_CONFIGURE is enabled, called LPUART_Deinit() at the start of mcux_lpuart_configure(), which disables the LPUART peripheral clocks. The requested configuration is validated only afterwards (in mcux_lpuart_configure_basic), and unsupported parity/data-bit/stop-bit/flow-control values return -ENOTSUP before the clock is re-enabled. As a result, a uart_configure() request with an unsupported configuration left the LPUART in a clock-disabled state; any subsequent access to LPUART registers (poll_out/poll_in, interrupt handling, or a later reconfigure) faults on the gated peripheral and escalates to a hard fault, crashing the system. uart_configure() is a Zephyr syscall whose verifier (z_vrfy_uart_configure) only checks that cfg is readable user memory and forwards the caller-supplied configuration unchanged, so an unprivileged userspace thread with access to an LPUART device can deterministically trigger the fault, a persistent system-wide denial of service. Introduced in v2.5.0 and present in all subsequent releases until this fix, which removes the LPUART_Deinit() call and instead only disables the transmitter/receiver, leaving the clock running. It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2026-10674? +
CVE-2026-10674 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
How do I check if I'm vulnerable to CVE-2026-10674? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-10674 — free, no signup required.