CVE-2025-30655

MEDIUM
Published Apr 9, 2025 Modified Jan 23, 2026 CWE-754

Description

An Improper Check for Unusual or Exceptional Conditions vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privileged attacker to cause a Denial-of-Service (DoS). When a specific "show bgp neighbor" CLI command is run, the rpd cpu utilization rises and eventually causes a crash and restart. Repeated use of this command will cause a sustained DoS condition.  The device is only affected if BGP RIB sharding and update-threading is enabled. This issue affects Junos OS:  * All versions before 21.2R3-S9,  * from 21.4 before 21.4R3-S8, * from 22.2 before 22.2R3-S6,  * from 22.4 before 22.4R3-S2,  * from 23.2 before 23.2R2-S3,  * from 23.4 before 23.4R2. and Junos OS Evolved:  * All versions before 21.2R3-S9-EVO,  * from 21.4-EVO before 21.4R3-S8-EVO,  * from 22.2-EVO before 22.2R3-S6-EVO,  * from 22.4-EVO before 22.4R3-S2-EVO,  * from 23.2-EVO before 23.2R2-S3-EVO,  * from 23.4-EVO before 23.4R2-EVO.

Is your site exposed to CVE-2025-30655?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Weakness Type (CWE)

CWE-754 CWE-754

Affected Products

Vendor Product
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved
juniper junos_os_evolved

References

Frequently Asked Questions

What is CVE-2025-30655? +
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privileged attacker to cause a Denial-of-Service (DoS). When a specific "show bgp neighbor" CLI command is run, the rpd cpu utilization rises and eventually causes a crash and restart. Repeated use of this command will cause a sustained DoS condition.  The device is only affected if BGP RIB sharding and update-threading is enabled. This issue affects Junos OS:  * All versions before 21.2R3-S9,  * from 21.4 before 21.4R3-S8, * from 22.2 before 22.2R3-S6,  * from 22.4 before 22.4R3-S2,  * from 23.2 before 23.2R2-S3,  * from 23.4 before 23.4R2. and Junos OS Evolved:  * All versions before 21.2R3-S9-EVO,  * from 21.4-EVO before 21.4R3-S8-EVO,  * from 22.2-EVO before 22.2R3-S6-EVO,  * from 22.4-EVO before 22.4R3-S2-EVO,  * from 23.2-EVO before 23.2R2-S3-EVO,  * from 23.4-EVO before 23.4R2-EVO. It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2025-30655? +
CVE-2025-30655 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
What products are affected by CVE-2025-30655? +
CVE-2025-30655 affects products from juniper, specifically: junos, junos_os_evolved. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2025-30655? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2025-30655 — free, no signup required.