CVE-2025-21840

MEDIUM
Published Mar 7, 2025 Modified Oct 29, 2025

Description

In the Linux kernel, the following vulnerability has been resolved: thermal/netlink: Prevent userspace segmentation fault by adjusting UAPI header The intel-lpmd tool [1], which uses the THERMAL_GENL_ATTR_CPU_CAPABILITY attribute to receive HFI events from kernel space, encounters a segmentation fault after commit 1773572863c4 ("thermal: netlink: Add the commands and the events for the thresholds"). The issue arises because the THERMAL_GENL_ATTR_CPU_CAPABILITY raw value was changed while intel_lpmd still uses the old value. Although intel_lpmd can be updated to check the THERMAL_GENL_VERSION and use the appropriate THERMAL_GENL_ATTR_CPU_CAPABILITY value, the commit itself is questionable. The commit introduced a new element in the middle of enum thermal_genl_attr, which affects many existing attributes and introduces potential risks and unnecessary maintenance burdens for userspace thermal netlink event users. Solve the issue by moving the newly introduced THERMAL_GENL_ATTR_TZ_PREV_TEMP attribute to the end of the enum thermal_genl_attr. This ensures that all existing thermal generic netlink attributes remain unaffected. [ rjw: Subject edits ]

Is your site exposed to CVE-2025-21840?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Affected Products

Vendor Product
linux linux_kernel
linux linux_kernel
linux linux_kernel

References

Frequently Asked Questions

What is CVE-2025-21840? +
In the Linux kernel, the following vulnerability has been resolved: thermal/netlink: Prevent userspace segmentation fault by adjusting UAPI header The intel-lpmd tool [1], which uses the THERMAL_GENL_ATTR_CPU_CAPABILITY attribute to receive HFI events from kernel space, encounters a segmentation fault after commit 1773572863c4 ("thermal: netlink: Add the commands and the events for the thresholds"). The issue arises because the THERMAL_GENL_ATTR_CPU_CAPABILITY raw value was changed while intel_lpmd still uses the old value. Although intel_lpmd can be updated to check the THERMAL_GENL_VERSION and use the appropriate THERMAL_GENL_ATTR_CPU_CAPABILITY value, the commit itself is questionable. The commit introduced a new element in the middle of enum thermal_genl_attr, which affects many existing attributes and introduces potential risks and unnecessary maintenance burdens for userspace thermal netlink event users. Solve the issue by moving the newly introduced THERMAL_GENL_ATTR_TZ_PREV_TEMP attribute to the end of the enum thermal_genl_attr. This ensures that all existing thermal generic netlink attributes remain unaffected. [ rjw: Subject edits ] It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2025-21840? +
CVE-2025-21840 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
What products are affected by CVE-2025-21840? +
CVE-2025-21840 affects products from linux, specifically: linux_kernel. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2025-21840? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2025-21840 — free, no signup required.