CVE-2022-49504

MEDIUM
Published Feb 26, 2025 Modified Oct 21, 2025

Description

In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Inhibit aborts if external loopback plug is inserted After running a short external loopback test, when the external loopback is removed and a normal cable inserted that is directly connected to a target device, the system oops in the llpfc_set_rrq_active() routine. When the loopback was inserted an FLOGI was transmit. As we're looped back, we receive the FLOGI request. The FLOGI is ABTS'd as we recognize the same wppn thus understand it's a loopback. However, as the ABTS sends address information the port is not set to (fffffe), the ABTS is dropped on the wire. A short 1 frame loopback test is run and completes before the ABTS times out. The looback is unplugged and the new cable plugged in, and the an FLOGI to the new device occurs and completes. Due to a mixup in ref counting the completion of the new FLOGI releases the fabric ndlp. Then the original ABTS completes and references the released ndlp generating the oops. Correct by no-op'ing the ABTS when in loopback mode (it will be dropped anyway). Added a flag to track the mode to recognize when it should be no-op'd.

Is your site exposed to CVE-2022-49504?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Affected Products

Vendor Product
linux linux_kernel

References

Frequently Asked Questions

What is CVE-2022-49504? +
In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Inhibit aborts if external loopback plug is inserted After running a short external loopback test, when the external loopback is removed and a normal cable inserted that is directly connected to a target device, the system oops in the llpfc_set_rrq_active() routine. When the loopback was inserted an FLOGI was transmit. As we're looped back, we receive the FLOGI request. The FLOGI is ABTS'd as we recognize the same wppn thus understand it's a loopback. However, as the ABTS sends address information the port is not set to (fffffe), the ABTS is dropped on the wire. A short 1 frame loopback test is run and completes before the ABTS times out. The looback is unplugged and the new cable plugged in, and the an FLOGI to the new device occurs and completes. Due to a mixup in ref counting the completion of the new FLOGI releases the fabric ndlp. Then the original ABTS completes and references the released ndlp generating the oops. Correct by no-op'ing the ABTS when in loopback mode (it will be dropped anyway). Added a flag to track the mode to recognize when it should be no-op'd. It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2022-49504? +
CVE-2022-49504 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
What products are affected by CVE-2022-49504? +
CVE-2022-49504 affects products from linux, specifically: linux_kernel. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2022-49504? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2022-49504 — free, no signup required.